In this article
Overview
You can use this Snap to remove an element from a parent Bill of Materials (BOM) node in the Teamcenter software.
Snap Type
The PLM TC BOM Structure Remove Snap is a write-type Snap that removes the element from a parent BOM node.
Prerequisites
None.
Known Issues
None.
Snap Views
Type | Format | Number of Views | Examples of Upstream and Downstream Snaps | Description |
---|---|---|---|---|
Input | Document |
|
| The parent ID, child ID and the attributes that needs to be fetched from the Teamcenter. |
Output | Document |
|
| The parent BOM node with the specified element deleted. |
Error | Error handling is a generic way to handle errors without losing data or failing the Snap execution. You can handle the errors that the Snap might encounter when running the Pipeline by choosing one of the following options from the When errors occur list under the Views tab:
Learn more about Error handling in Pipelines. |
Snap Settings
Asterisk ( * ): Indicates a mandatory field.
Suggestion icon (): Indicates a list that is dynamically populated based on the configuration.
Expression icon ( ): Indicates the value is an expression (if enabled) or a static value (if disabled). Learn more about Using Expressions in SnapLogic.
Add icon ( ): Indicates that you can add fields in the field set.
Remove icon ( ): Indicates that you can remove fields from the field set.
Upload icon ( ): Indicates that you can upload files.
Field Name | Field Type | Description |
---|---|---|
Label*
Default Value: PLM TC BOM Structure Add | String | The name for the Snap. You can modify this to be more specific, especially if you have more than one of the same Snap in your pipeline.
|
Parent ID* Default Value: N/A | String/Expression | Specify the _id or an UID of the parent folder where you want to add the new item. |
Child ID* Default Value: N/A | String/Expression | Specify the _id, a UID or a Teamcenter adapter ID of the child. |
Revision Rule*
Default Value: N/A | String/Expression/Suggestion | Specify the revision rule that you want the Snap to use for the structure expansion. |
View type Default Value: N/A | String/Expression/Suggestion | Specify the view type to determine the layout, visibility, and organization of data in the Teamcenter software. The view type is a predefined set of properties and display settings used to present information about an object or a specific aspect of the system's functionality. |
Snap Execution Default Value: | Dropdown list | N/A |
Troubleshooting
Error | Reason | Resolution |
---|---|---|
Unable to start the embedded Teamcenter Adapter. | The PLM TC requires SOA API Libraries. The required SOA API Libraries are unavailable in the JCC (Java Command Center) environment. | Copy the required API library files to the %SL_ROOT%/teamcenter_lib directory. Then, ensure they are added to SL_CLASSPATH. Verify the correct library setup. |
Communication failure with the PLM TC Snap. The host cannot be connected. | The configured hostname cannot be resolved to an IP address. |
|
The connection failed when connecting to the Teamcenter software. | Communication with the Teamcenter Webtier cannot be established because of firewall settings or incorrect URL/port configuration. | Investigate if there's a firewall between the Groundplex and the Teamcenter server. Verify the URL and port settings. |
Incorrect account credentials. | The username and password provided in the account configuration are incorrect. | Ensure that the correct username and password are configured in the account. |
Invalid user or user does not exist. | The user configured in the account is set to inactive in Teamcenter software. | Reactivate the user account in the Teamcenter software through an authorized user, typically an administrator. |