Users must add credentials for Gainsight PX and Zendesk in AutosyncAutoSync, not in the IIP or AutoSync Manager.
Integrations with Zendesk as a source and Google BigQuery as a destination may fail to load records when using the SCD2 load type.
Data pipelines with Oracle as the source and Snowflake as the destination incorrectly report the number of updated records when using the Incremental load type. For example, when a record is added, the details show that it was added and updated. The issue occurs because Oracle has the capability to store timestamps with precision down to a nanosecond nanoseconds (by default it , precision is microsecondmicroseconds), but AutoSync timestamps are limited to millisecond precision. Incremental loads depend on the timestamp, and if a record update occurs only nanoseconds after the previous update, AutoSync does not recognize it as an update.
...