Skip to end of banner
Go to start of banner

PLM TC BOM Structure Remove

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 11 Next »

In this article

Overview

You can use this Snap to remove an element from a parent Bill of Materials (BOM) node in the Teamcenter software.

Snap Type

The PLM TC BOM Structure Remove Snap is a write-type Snap that removes the element from a parent BOM node.

Prerequisites

None.

Known Issues

None.

Snap Views

Type

Format

Number of Views

Examples of Upstream and Downstream Snaps

Description

Input 

Document

  • Min: 0

  • Max: 1

  • Mapper

  • JSON Generator

The parent ID, child ID and the attributes that needs to be fetched from the Teamcenter.

Output

Document

  • Min: 1

  • Max: 1

  • PLM TC BOM Structure Add

  • PLM TC BOM Structure Get Recursive

The parent BOM node with the specified element deleted.

Error

Error handling is a generic way to handle errors without losing data or failing the Snap execution. You can handle the errors that the Snap might encounter when running the Pipeline by choosing one of the following options from the When errors occur list under the Views tab:

  • Stop Pipeline Execution: Stops the current pipeline execution if the Snap encounters an error.

  • Discard Error Data and Continue: Ignores the error, discards that record, and continues with the remaining records.

  • Route Error Data to Error View: Routes the error data to an error view without stopping the Snap execution.

Learn more about Error handling in Pipelines.

Snap Settings

  • Asterisk ( * ): Indicates a mandatory field.

  • Suggestion icon ((blue star)): Indicates a list that is dynamically populated based on the configuration.

  • Expression icon ((blue star) ): Indicates the value is an expression (if enabled) or a static value (if disabled). Learn more about Using Expressions in SnapLogic.

  • Add icon ( (blue star) ): Indicates that you can add fields in the field set.

  • Remove icon ( (blue star)): Indicates that you can remove fields from the field set.

  • Upload icon ((blue star) ): Indicates that you can upload files.

Field Name

Field Type

Description

Label*

 

Default Value PLM TC BOM Structure Add
ExamplePLM TC BOM Structure add

String

The name for the Snap. You can modify this to be more specific, especially if you have more than one of the same Snap in your pipeline.

 

Parent ID*

Default Value: N/A
Example: Client details

String/Expression

Specify the _id or an UID of the parent folder where you want to add the new item.

Child ID*

Default Value: N/A
Example: new client_tc

String/Expression

Specify the _id, a UID or a Teamcenter adapter ID of the child.

Revision Rule*

 

Default Value: N/A
Example: 3<1

String/Expression/Suggestion

Specify the revision rule that you want the Snap to use for the structure expansion.

View type

Default Value: N/A
Example: Queryview

String/Expression/Suggestion

Specify the view type to determine the layout, visibility, and organization of data in the Teamcenter software. The view type is a predefined set of properties and display settings used to present information about an object or a specific aspect of the system's functionality.

Snap Execution

Default Value
Example: Validate & Execute

Dropdown list

N/A

Troubleshooting

Error

Reason

Resolution

Unable to start the embedded Teamcenter Adapter.

The PLM TC requires SOA API Libraries. The required SOA API Libraries are unavailable in the JCC (Java Command Center) environment.

Copy the required API library files to the %SL_ROOT%/teamcenter_lib directory. Then, ensure they are added to SL_CLASSPATH. Verify the correct library setup.

Communication failure with the PLM TC Snap. The host cannot be connected.

The configured hostname cannot be resolved to an IP address.

  • Hostname Check: Verify and correct the hostname.

  • DNS Configuration: Check and correct the DNS configuration.

The connection failed when connecting to the Teamcenter software.

Communication with the Teamcenter Webtier cannot be established because of firewall settings or incorrect URL/port configuration.

Investigate if there's a firewall between the Groundplex and the Teamcenter server. Verify the URL and port settings.

Incorrect account credentials.

The username and password provided in the account configuration are incorrect.

Ensure that the correct username and password are configured in the account.

Invalid user or user does not exist.

The user configured in the account is set to inactive in Teamcenter software.

Reactivate the user account in the Teamcenter software through an authorized user, typically an administrator.

Snap Pack History

 Click here to expand...

Release

Snap Pack Version

Date

Type

Updates

August 2024

main180

21 Aug 2024

Stable

Updated and certified against the current SnapLogic Platform release.

May 2024

main172

Stable

Updated and certified against the current SnapLogic Platform release.

February 2024

main156

Stable

Updated and certified against the current SnapLogic Platform release.

November 2023

main155

Stable

Updated and certified against the current SnapLogic Platform release.

September 2023

main148

Latest/Stable

Introduced the PLM TC. It has the following two accounts:

  • PLM TC Account

  • PLM TC Adapter Account

This Snap Pack includes 35 Snaps that perform various functions, including:

  • BOM Structure Management

  • Data Management

  • Workflow Management

  • Requirements Management

  • Product Management


Related Content

  • No labels